Insertion and Return Loss
     
    Connected Fibers, LLC. - Connecting People to Quality Fiber Optic Technology

 

 

       

NewsServicesWhite PapersContact UsAbout Us

OptoTest OP930 Insertion and Return Loss Test Set

Insertion loss (IL) and return loss (RL) on fiber optical components are measured fast and accurately with the OP930. The return loss is measured with the "no mandrel" method, meaning neither matching gel nor mandrel wraps are required at the far end of the cable. The insertion loss is measured by utilizing the stable transmitter of the return-loss as the source in combination with the precision optical power meter.
Like other OptoTest equipment the OP930 supports the USB interface. The OPL-PRO turnkey application software fully integrates this instrument into the data acquisition process of the high efficient production line.

 

Key Features :

Fully automated, concurrent dual wavelength IL and RL.

Both readings, insertion loss and return loss at the same time

Multimode return loss to qualify GbE cables

USB Interface to custom application or included OPL9 application support writing directly to a spreadsheet

 

Optical Power Measurement

No mandrel wrap nor matching gel

Singlemode: 10dB to >72dB Return Loss

Multimode: 10dB to 50dB Return Loss

 

Return Loss Measurement

State of the art fiber optic power meter

Various detector options for single fiber, MT-RJ and MTP/MPO multifiber connectors

Automated dual wavelength insertion loss measurement

Specifications

Models

OP930-SM-13/15,OP930-SM-1310

OP930-SM-1550

OP930-MM-85/13, OP930-MM-850

OP930-MM-1300

Power Meter Operation (Detector Port)

   

Measurement Range

+3 to –80dBm +3 to –80dBm

Measurement Linearity(1)

+/- 0.05dB (+0dBm to – 65dBm)

Wavelength Dependency

see Spectral Responsivity

Calibration Wavelength(2)

850nm, 980nm, 1300nm, 1310nm, 1480nm, 1550nm, 1625nm

Calibration Traceability

U.S. N.I.S.T.

Absolute Accuracy

±0.25 dB at calibration conditions for all NIST traceable wavelengths

Stability(3)

<+/- 0.02dB (3dBm to –65dBm)

Resolution

0.001 dB

Recommended Calibration Period

12 months

Settling Time

(auto-range from dark to max. power.)

0.2 seconds (0dBm to –80dBm)

Number of readings/sec. (in remote mode)

≥ 10 readings per second

Measurement Performance

Internal sampling interval approx. 35msec

Measurement Modes

dBm, dB
Optical Connector Interface OptoTest adapter system for FC, ST, SC, LC, E2000, others
Source Operation (Source Port)  
Source Wavelength(4) 1310nm, 1550nm or both 850nm, 1300nm, or both
Source Type stabilized FP Laser stabilized LED Source
Output Power(5) typical -3dBm typical -20 dBm (62.5/125μum)typical -20 dBm (50/125μum)
Power Stability  +/-0.05dB +/- 0.05dB
Fiber Compatibility (internal fiber) 9/125 (SMF-28) 62.5/125 GI multimode
Optical Interface APC polish only APC polish only (requires MM reference cable)
Launch Condition NA
Source Switching Time <0.1sec <0.3sec
Referencing Cycle <5 sec
 
 

(1) Measured at wavelength of 1480nm for 1mm detector. Other detector types or sizes may have a lower specification.

(2) All Calibrated wavelengths are NIST traceable and are calibrated at -10dBm

(3) Within specified ambient environmental temperature of 20°C to 25°C, stable within +/- 2°C

(4) All actual center wavelengths are +/-30nm from the nominal value for all source types.